Huge damage and loss occur most frequently when leaks are
undetected over extended periods. Moreover, presence of leak can be difficult
to find. This puts risks to the equipment and assets and can cause tremendous
damage once left unnoticed. Therefore, a risk management is critically
important to prevent such event.
LEAK DETECTION SYSTEM is an essential component of
risk management as it can detect leaks quickly, locate it accurately, issue
false alarms, and work effectively under all operating conditions.
Partnered with Tracetek the pioneer of Leak Detection
System, we give out a solution that will detect leaks on its early age.
A leak detection system which provides high accuracy
readings once a leak has been detected and immediately alert you to prevent a
bigger situation. It helps the operators responds in time to the leaks and work
to its maximum efficiency.
A reliable system with proven track records in the
application in offices, hotels, museums, computer rooms, data centers or other
commercial buildings.
TRACETEK
Leak Detection System is an essential component of risk management as it
can detect leaks quickly, locate it accurately, issue false alarms, and work
effectively under all operating conditions. Partnered with Tracetek the pioneer
of the Leak Detection System, we give out a solution that will detect leaks at
an early age.
A leak detection system which provides high accuracy readings once a
leak has been detected and immediately alert you to prevent a bigger situation.
A reliable system with proven track records in the application in offices,
hotels, museums, computer rooms, data centers or other commercial buildings.
WATER LEAK DETECTION
The presence of water in data centers and computer rooms can cause
damage to cables, servers, and network equipment. Even just a small, unnoticed
leak may cause tremendous damage to the functionality of the equipment and the
data it stores. Without a water leak detection system, oftentimes problem goes
undetected until it is too late.
This is why monitoring any water build-up in these areas is necessary,
and a good and reliable water leak detection system is critically important.
Linkwise technology offers a water leak detection system that provides
high accuracy readings once a leak has been detected and immediately alert you
to prevent the bigger situation. A reliable system with proven track records in
the application in offices, hotels, museums, computer rooms, data centers or
other commercial buildings.
TT1000
Tracetek TT1000 sensing cables detect the presence
of water at any point along their length. Installed with the Tracetek module.
TT1100-OHP
The TT1100-OHP sensor cable is designed for use on
insulated pipes. It detects water presence at any point
along their length.
TT-FLAT PROBE
The TT-FLAT PROBE is a special purpose probe
designed to detect water l Leaks in specific locations.
FUEL LEAK DETECTION
Companies engaging with fuels, manufacturing or airlines are prone to
safety issues most especially on how they will monitor and prevent leakage that
may cause a serious problem on their day to day operation.
Linkwise provides a Fuel Leak Detection System designed to detect fuel leak below ground or above ground, long before it became a large spill. Equipped with sensors which can pinpoint the source of the leak and respond to the source of the leak immediately.
Linkwise provides a Fuel Leak Detection System designed to detect fuel leak below ground or above ground, long before it became a large spill. Equipped with sensors which can pinpoint the source of the leak and respond to the source of the leak immediately.
Accurate and reliable fuel leak detection system, that will give you
security and complete assurance.
TT5000-SC
TT5000-SC is for double containment piping systems,
indoor day tanks, pumps, and valve pads.
TT5000-HS
TT5000-HS is for use in slotted conduit installed
below grade beside pipelines and under tank or buried valves.
TT5000-HUV
TT5000-HUV is used for the above-ground piping
around tanks and other locations exposed to sunlight.
TTFFS
TTFFS-100 detects liquid hydrocarbon fuels such as
naphtha, refined products and heavy crude.
CONDUCTIVE LEAK DETECTION
In some industries, water and fuel are not the only
problems. Leakage of conductive liquid can also be a problem such as acid,
chemicals and even hazardous waste which will severely affect the
operation. Even a small leak can cause a big effect, which may result in a
panic, complete shutdown of the facility, and the environmental case may be
filed against the company.
Linkwise Technology provides Conductive Liquids Leak Detection System
equipped with sensing cable which is dedicated to detecting early spills/leaks
of conductive liquid. It has a built-in alarm that will be able to detect the
location of the leak.
A cost-efficient system that will give you security
and complete assurance.
TT3000
Used to detect spills and leaks of aqueous
chemicals which include waste-water, acids, bases, hazardous waste streams,
etc.
TT-MINI-PROBE
The TT-MINI-PROBE can also be used to detect leaks
in drip trays or sumps, or low spots where TraceTek sensing cables are
inappropriate.
SOLVENT LEAK DETECTION
A solvent leak can be really dangerous as it involves hazardous waste.
It may put risks not just with your assets and production, but also with the
safety of the people.
Solvent leak detection system is an innovative solution which detects
early solvent leaks and prevent a problem that may cause a delay with the
day-to-day operation.
Linkwise provides a Solvent leak detection system, equipped with
reliable sensing cable, capable to detect liquid organic leak anywhere along
its length but does not react in the presence of water.
It has a built-in alarm that can pinpoint the location of leak.
A guaranteed cost-efficient solution to your problem.
TT5001
TT5001 sensing cable detects the liquid organic
solvents anywhere along its length, yet does not react to the presence of
water.
Installed with a TraceTek alarm and locating
module, the cable senses the liquid, triggers an alarm, and pinpoints the
location of the leak.
MODULES
TTSIM-1
The TTSIM-1 is a sensor interface module capable of
monitoring up to 1500 meters (5000 feet) of TraceTek sensing cable. When liquid
is detected.
The TTSIM-1 locates the leak and communicates the
leak details to the host of monitoring system
TTSIM-2
The TTSIM-2 sensor interface module monitors up to
150 meters (500 feet) of TraceTek sensing cable. When liquid is detected, the
TTSIM-2 unit indicates the leak, displays the location of the leak and switches
a relay to provide local voltage-free contact closure.
The TTSIM-2 can also communicate to a host
monitoring system such as TraceTek TTDM-128 or directly to a PLC or other host
system using standard protocols.
TTSIM-1A
TTSIM-1A is a primary sensor interface module with
the capacity to monitor up to 150 m (500ft) of sensor cable. The output is via
relay contacts and serial data.
TTDM-128
TRACETEK TTDM-128 is the primary user alarm panel
and system control unit for networked Tracetek systems.
GUARDSEN
GuardSen GS-LDC-1
GuardSen GS-LDC-1 sensing cables detect the
presence of water at any point along their length. Installed with a GuardSen
alarm module (GS-LDA-1), the cable senses water intrusion and triggers an
alarm. It provides distributed leak detection and location over a wide range of
areas.
The GS-LDC-1 sensing cables are available in a
variety of lengths to provide as much coverage as needed.
GuardSen GS-LDC-2
GuardSen GS-LDC-2 sensing cables detect the
presence of water at any point along their length. Installed with a GuardSen
alarm module (GS-LDA-2), the cable senses water intrusion and triggers an
alarm. It provides distributed leak detection and location over a wide range of
areas.
The GS-LDC-2 sensing cables are available in a variety of lengths to
provide as much coverage as needed.
GS-LDA-1
The GS-LDA-1 Sensor Interface Module monitors up to
500 meters of GuardSen sensing cable (GS-LDC-1). When liquid is detected, the
GS-LDA-1 unit indicates the leak with an LED and switches a relay to provide
local voltage-free contact closure.
The GS-LDA-1 can be used as a standalone leak
detection alarm unit or can also communicate to a host monitoring system such
as PLC or Monitoring System by using standard RS-485 communications.
GS-LDA-2
The GS-LDA-2 Sensor Interface Module monitors up to
1500 meters of GuardSen sensing cable (GS-LDC-2). When liquid is detected, the
GS-LDA-2 unit indicates the leak, displays the location of the leak and
switches a relay to provide local voltage-free contact closure.
The GS-LDA-2 can be used as standalone leak
detection alarm unit or can also communicate to a host monitoring system such
as PLC or other monitoring systems by using standard RS-485 protocols.
No comments: